HepatoGlo™-Tox HT

An In Vitro Standardized and Validated
ATP Bioluminescence Hepatotoxicity
Testing and High-Throughput Screening Platform


 

 

HepatoGLO™-Tox HT

A Standardized and Validated Vitro Bioluminescence Hepatotoxicity Assay Platform

Cell Population Species Medium Formulation Catalog Number Quantity
Hepatocytes (adherent) Any HepatoGro Specialized Growth Medium KHG-T96A-4 4 Plates/1 Kit
Hepatocytes (non-adherent) Any HepatoGro Specialized Growth Medium KHG-T96NA-4 4 Plates/1 Kit

 

HepatoGlo™-Tox HT: A standardized and validated ATP bioluminescence hepatotoxicity testing and screening platform

 

  • Hepatocytes have high intracellular concentrations of ATP. Changes in hepatocyte metabolism can be detected and measured using HepatoGLO™.
  • Specifically designed to screen and test for hepatotoxicity.
  • High throughput in vitro ADME/Tox screening.
  • Drug/agent toxicity ranking according to organ/tissue and species.
  • Incorporates proven ATP bioluminomics™ technology, the most sensitive signal detection system available.
  • Fully calibrated and standardized, and can be validated according to regulatory requirements.
  • Reliably compares results over time.
  • Available for adherent or non-adherent cells.
  • Flexible; HepatoGro™ Medium included, or use virtually any hepatocyte culture protocol.
  • Multiplexing capabilities.
  • Rapid turnaround.
  • Simple and time efficient.

Principle of ATPBioluminescence Cell Proliferation/Cytotoxicity Assays

All ATP bioluminescence assays kits from Preferred Cell Systems™ include an ATP standard(s) and controls.  Performing the ATP standard curve and controls is highly recommended. The controls are used to calibrate the instrument and the ATP standard is used to standardize the assay. The values obtained provide the measurement assurance parameters that allow you, the user, to ensure that the results obtained can be trusted.

An example of an ATP standard curve and control results are shown in the diagram below and actual values for the kit being used are given in the Technical Manual. If the values obtained are within the ranges given in the Technical Manual, the user can process the samples knowing that the results will be trustworthy.

Calibration and standardization of an ATP bioluminescence assay from Preferred Cell Systems™ - Measurement Assurance
 

Species

  • Human
  • Non-human primate
  • Dog
  • Rat
  • Mouse
  • Please inquire for other species

 

Hepatocytes

  • Fresh
  • Cryopreserved
  • Male
  • Female
  • Pooled
  • Induce pluripotent stem (iPS) cell-derived hepatocytes
  • Hepatocyte cell lines (e.g. Hep G2)

HepatoGlo5FU

Click image for larger view

HepatoGloDox

Click image for larger view

The two diagrams to the left compare the response of 5-fluorouracil and doxorubicin on cryopreserved human and rat hepatocytes. Notice the different scale on the Y-axis for the two species. Although hepatocytes do not represent a proliferating cell population under normal steady-state conditions, they are actively producing intracellular ATP. The difference in normal ATP production is shown on the Y-axis. For the examples shown here, HepatoGlo™-HT provides a reliable high throughput assay platform to detect hepatotoxicity during ADME/Tox screening.

 

HepatoGLO™-Tox HT assays are available with:

  • 96- or 384-well plates

For Research Use Only. Not for clinical diagnostic use.

Luminescence or multimode plate reader with "glow" luminescence measuring capability.

  • HepatoGro™ Medium
  • ATP standard
  • ATP controls
  • ATP Enumeration Reagent
  • Sterile, 96- or 384-well plates, depending on assay use
  • Non-sterile, 96- or 384-well plates, depending on assay use
  • Sterile, adhesive foil covers to maintain sterility of unused wells


Standardized and Complete Bioluminescence Hepatotoxicity Assay Platform

Download the HepatoGlo™-Tox HT Technical Manual
Download the ATP Optimization Kit Protocol for First-Time Users
Download the Luminometer Setup and RLU to ATP Conversion Protocol

Download Certificate of Analysis (CoAs) for ATP Enumeration Reagent (ATP-ER)
Download Certificate of Analysis for ATP Stanadrds
Download Certificate of Analysis for ATP Controls
Download Certificate of Analysis of ATP Reconstitution Reagent
Download Certificate of Analysis for Sterile 96-Well Plates
Download Certificate of Analysis for Non-Sterile, 96-Well Plates
Download Certificate of Analysis for Sealing Films
Download Certificate of Analysis for IMDM