EpiFLUOR™

An In Vitro Fluorescence Assay for Intestinal Cell Viability and Function


 

EpiFLUOR™

The Easy and Rapid In Vitro Research Fluorescence Assay for Intestinal Cells

Cell Population Species Medium Formulation Catalog Number Quantity
Intestinal cells (adherent) Any User defined KEF-A-1 1 Kit
Intestinal cells (non-adherent) Any User defined KEF-NA-1 1 Kit

EpiFluor™: An In Vitro Fluorescence Assay for Intestinal Viability and Function

 

 

  • Study intestinal epithelium stem cell research.
  • Measure stem cell self-renewal, proliferation potential and ability.
  • Study intestinal progenitor cells, cell differentiation and markers.
  • Study cell functional interaction.
  • Determine the response of crypt and villi cells to different agents.
  • Incorporates a non-destructive, highly accurate alamarBlue™ fluorescence reagent.
  • Uses a fluorescence plate reader or multimode plate reader with an excitation filter at 560nm and an emission filter at 590nm.
  • Non-subjective, instrument-based and quantitative readout procedure.
  • Easily multiplexes with other fluorescent labels/markers.
  • Combine with gene expression assays etc or other endpoints for more information from a single sample.
  • Flexibility to use the investigators own growth medium and protocols.
  • High throughput capability.
  • Results in 1-3 hours after adding reagent.
  • Simple, time efficient and cost effective.

Principle of Using STEMFluor to Measure Cell Proliferation using a Fluorescence Resazurin Readout
 

EpiFluor™ can be used to study the intestine from multiple species. EpiFluor™ can also be used for intestinal cell lines.

  • Incorporates the measurement of non-fluorescent Resazurin (alamarBlue™) to fluorescent Resorufin in an oxidation/reduction reaction that occurs only in live cells. The amount of fluorescence (relative fluorescence units, RFU) is dependent on the metabolic status of the cells and therefore is not only a measure of metabolic viability, but cell proliferation or inhibition.
  • After culture, add 10μL of reagent, mix and measure signal between 30 minutes and 4 hours in a fluorescence plate reader.
  • Uses a plate fluorometer or multi mode plate reader to measure fluorescence with an excitation filter 560nm and an emission filter of 590nm.

For Research Use Only. Not for clinical diagnostic use.
Fluorescence or multimode plate reader with a 560nm excitation and 590nm emission filter.

  • AlamarBlue™/Resazurin Reagent.
  • 3% SDS solution to stop the reaction.
  • Resorufin to standardize the assay.
  • Non-sterile, black, 96-well plates for assay standardization.
  • Sterile, black, 96-well plates, for cardiac myocyte culture. Choice of adherent or non-adherent plates.
  • Sterile, adhesive foil covers to maintain sterility of unused wells.
EpiFLUOR™ has the flexibility to be used with virtually any growth medium and culture protocol.